[Jan-2023] 5V0-21.21 Exam Questions and Valid 5V0-21.21 Dumps PDF [Q21-Q43]

Share

[Jan-2023] 5V0-21.21 Exam Questions and Valid 5V0-21.21 Dumps PDF

5V0-21.21 Brain Dump: A Study Guide with Tips & Tricks for passing Exam


VMware 5V0-21.21 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Given a scenario, identify how to apply the appropriate maintenance mode option
  • Given a scenario, identify the apDropriate action to recover from a vSAN or infrastructure failure
Topic 2
  • Given a scenario, identify the implications of integrating VMware solutions with vSAN
  • Given a scenario, identify the use cases for an HCI Mesh infrastructure
Topic 3
  • VMware Products and Solutions
  • Given a scenario, identify the VMware products and solutions that will interact with a vSAN solution

 

NEW QUESTION 21
An architect collected the below technical requirements from the customer during a vSAN cluster design workshop:
* Maximize the vSAN datastore usable capacity.
* Deduplication and compression are required to help utilize available capacity efficiency.
* Ensure the highest level of resiliency wherever possible.
Which disk group configuration should the architect include in the design?

  • A. Two disk groups per host, each with one cache tier flash disk and four capacity tier flash disks.
  • B. Two disk groups per host, each with one cache tier flash disk and six capacity tier magnetic disks.
  • C. Two disk groups per host, each with one cache tier flash disk and six capacity tier flash disks.
  • D. One disk group per host, with one cache tier flash disk and four capacity tier flash disks.

Answer: C

 

NEW QUESTION 22
An administrator wants to deploy Kubernetes on an end-to-end VMware stack, using VMware vSAN for storage.
Which VMware product should the administrator install as the Kubernetes platform choice?

  • A. VMware Tanzu Mission Control
  • B. VMware Tanzu Build service
  • C. VMware Tanzu Data services
  • D. VMware Tanzu Kubernetes Grid

Answer: D

Explanation:
Reference:
https://docs.vmware.com/en/VMware-Tanzu-Kubernetes-Grid-Integrated-Edition/index.html There is a picture with integration with vSAN

 

NEW QUESTION 23
An administrator is planning to deploy cloud-native workloads onto the vSAN Direct datastore.
Which storage policy structure rule is supported?

  • A. Storage performance-based rules
  • B. vVOL storage rules
  • C. Tag-based placement rules
  • D. Host-based rules

Answer: D

 

NEW QUESTION 24
Which statement accurately describes the result when proper VM Storage Policy Affinity Rules on a stretched vSAN cluster are set?

  • A. Proper policies result in higher inter-site bandwidth utilization.
  • B. When a site is disconnected, the VM will continue to have access to its VMDK.
  • C. When a site is disconnected, the VM will lose access to its VMDK.
  • D. Bandwidth is unnecessarily sent across the inter-site link.

Answer: C

 

NEW QUESTION 25
During a vSAN design workshop, an architect collected these customer requirements:
* Leverage vSAN storage policies with Erasure Coding.
* Enable Deduplication and Compression.
* Use the minimum number of hosts in the cluster.
* Maintain full storage policy compliance when two nodes are down.
Which vSAN cluster design meets the customer's requirements?

  • A. Six nodes Hybrid vSAN cluster
  • B. Six nodes All-Flash vSAN cluster
  • C. Five nodes All-Flash vSAN cluster
  • D. Five nodes Hybrid vSAN cluster

Answer: B

 

NEW QUESTION 26
An organization has two vSAN clusters managed by the same vCenter Server, each providing 100TB of storage. The first cluster runs at 75% of its storage capacity, and the second cluster runs at 50% of its storage capacity.
The company also has the following:
* An iSCSI array of 300TB. which runs at 76% of its capacity
* A NAS system of 200TB, which runs at 10% of its capacity
* A Fiber channel (FC) array of 300TB, which runs at 80% of its capacity The administrator is asked to add an additional 25TB of storage to the first cluster. The administrator is also made aware that there is no budget to purchase new hardware and that the vSAN Storage Policy Based Management must be kept in place.
Which storage option will work for this use case?

  • A. Obtain additional free capacity from the existing NAS storage.
  • B. Create an HCI Mesh using the first cluster's datastore.
  • C. Create an HCI Mesh using the second cluster's datastore.
  • D. Obtain additional free capacity from the existing FC storage.

Answer: C

Explanation:
https://blogs.vmware.com/virtualblocks/2020/09/16/introducing-vmware-vsan-hci-mesh/

 

NEW QUESTION 27
An architect is working with vSAN and setting the fault domains to support FTT=1.
How many fault domains will be needed?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B

 

NEW QUESTION 28
multiple data centers, the customer relayed the following information:
* Highest possible mitigation during a host failure in terms of capacity.
* A constraint in this year's IT budget.
What should the architect recommend?

  • A. Enable IOInsight Metrics.
    A minimum cluster of 2 vSAN ROBO nodes.
  • B. Enable performance services.
    A minimum cluster of 6 vSAN nodes.
  • C. Enable operations reserve.
    A minimum cluster of 3 vSAN nodes.
  • D. Enable host build reserve.
    A minimum cluster of 4 vSAN nodes.

Answer: D

Explanation:
Performance services and IOinsight Metrics used for performance analysis. Operation reserve for internal VSAN operations. https://blogs.vmware.com/virtualblocks/2020/09/24/effective-capacity-management-with-vsan-7-update-1/

 

NEW QUESTION 29
An administrator has been tasked to reboot a node in an encrypted vSAN cluster. The vSAN disk groups on that node become locked after rebooting the node.
Which step should be performed to exit the locked state?

  • A. Replace the caching device in each affected disk group.
  • B. Run /etc/init.d/vsanvpd restart to rescan the VASA providers.
  • C. Restore the communication with the KMS server, and re-establish the trust relationship.
  • D. Manually replace the Host Encryption Key (HEK) of each affected host.

Answer: C

 

NEW QUESTION 30
An administrator wants to deploy a desktop and application virtualization solution on top of vSAN.
Which VMware product should the administrator install?

  • A. VMware Horizon Apps
  • B. VMware Horizon
  • C. VMware Workspace One Access
  • D. VMware Dynamic Environment Manager

Answer: B

 

NEW QUESTION 31
A 4-node vSAN cluster is configured with an erasure coding storage policy. The Ensure Accessibility maintenance mode was selected. While performing the maintenance, a second node fails.
What will be the impact on the vSAN cluster?

  • A. There will be no impact on performance.
  • B. The performance will be degraded.
  • C. The VMs will no longer be accessible.
  • D. The VMs will be in a suspended state.

Answer: A

 

NEW QUESTION 32
An administrator has received an alert indicating that a single capacity device is close to failing within the production vSAN Cluster. The administrator must now complete preemptive maintenance on the vSAN Cluster without impacting the availability of workloads or vSAN File Services.
The following information is known about the vSAN Cluster:
* vSAN 7.x Cluster
* vSAN node count: 8
* De-Duplication and Compression: Enabled.
* Encryption: Disabled
* Current Utilization: 45%
* Disk Groups: 2
* Devices per node: 2 x 400 GB SSD, 6 x 1.8 TB SSD
Which three steps should the administrator take to successfully complete the task? (Choose three.)

  • A. Replace the failed disk with a storage device that is identical in class but smaller in capacity.
  • B. Replace the failed disk with a storage device that is identical in class and capacity.
  • C. Remove the affected Disk Group from the vSAN Cluster, and choose Full Data Migration.
  • D. Remove the affected Disk from the Disk Group, and choose Full Data Migration.
  • E. Remove the affected Disk Group from the vSAN Cluster, and choose No Data Migration.
  • F. Put the affected vSAN host into maintenance mode to physically replace the storage device.

Answer: B,C,D

 

NEW QUESTION 33
An administrator wants to check the performance metrics for the workloads and their virtual disks that are running on a vSAN cluster, but no statistical charts are displayed in the vSphere client.
Why is this behavior being seen?

  • A. vSAN performance verbose mode is not enabled.
  • B. vSAN proactive tests haven't been run yet.
  • C. vSAN performance service is turned off.
  • D. vSAN network diagnostic mode is not enabled.

Answer: C

Explanation:
Some tools allow for measuring latency peaks. This unfortunately isn't ideal, as it can unfairly represent statistical outliers, which may very well occur when there is little to no I/O activity. The best way to understand the actual behavior of VM and application latencies is to observe in time based performance graphs. Depending on the level of detail, you may need to measure at the individual VMDK level. Become familiar with these graphs to determine what is normal, and what is not for that given application. This is where you can use built-in functionality of vCenter and the vSAN performance service metrics to gather this information.
Reference:
https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.vsan-monitoring.doc/GUID-EF27701E-7BAC-4E76-9D2F-E1C58CAAB06D.html

 

NEW QUESTION 34
An administrator of "vsan-prod" cluster noticed the witness components of VMs are flagged as absent after a failed attempt to replace the vSAN Witness Host.
Which action should the administrator take to resolve this issue?

  • A. Running the vSAN Skyline Health check to ensure there are vSAN Object Health errors and executing the Repair Object Immediately option
  • B. Upgrading the vSAN on-disk format
  • C. Placing the vSAN Witness Host in Maintenance Mode and adding to the vSAN cluster
  • D. Using the RVC command: vsan.resync_dashboard ~/computers/vsan-prod

Answer: C

 

NEW QUESTION 35
In a vSAN stretched cluster, which value must be set in the vSAN policy if there is no requirement for data mirroring across sites?

  • A. PFTT = 0
  • B. PFTT = 1
  • C. SFTT = 0
  • D. SFTT = 1

Answer: C

 

NEW QUESTION 36
An administrator has received an alert indicating that a single capacity device is close to failing within the production vSAN Cluster. The administrator must now complete preemptive maintenance on the vSAN Cluster without impacting the availability of workloads or vSAN File Services.
The following information is known about the vSAN Cluster:
* vSAN 7.x Cluster
* vSAN node count: 8
* De-Duplication and Compression: Enabled.
* Encryption: Disabled
* Current Utilization: 45%
* Disk Groups: 2
* Devices per node: 2 x 400 GB SSD, 6 x 1.8 TB SSD
Which three steps should the administrator take to successfully complete the task? (Choose three.)

  • A. Replace the failed disk with a storage device that is identical in class but smaller in capacity.
  • B. Remove the affected Disk Group from the vSAN Cluster, and choose Full Data Migration.
  • C. Replace the failed disk with a storage device that is identical in class and capacity.
  • D. Put the affected vSAN host into maintenance mode to physically replace the storage device.
  • E. Remove the affected Disk from the Disk Group, and choose Full Data Migration.
  • F. Remove the affected Disk Group from the vSAN Cluster, and choose No Data Migration.

Answer: C,D,E

Explanation:
If you upgrade the capacity device, verify the following requirements:
- Verify that the cluster contains enough space to migrate the data from the capacity device.
- Place the host in maintenance mode. See Place a Member of Virtual SAN Cluster in Maintenance Mode.
"Select the flash capacity device or magnetic disk, and click Remove selected disk(s) from disk group."
https://docs.vmware.com/en/VMware-vSphere/6.5/com.vmware.vsphere.virtualsan.doc/GUID-4E3390C1-6C50-49E5-AEB6-C9BC037979A1.html

 

NEW QUESTION 37
An administrator is setting up vSAN file services on a vSAN cluster.
Which two security policies on the distributed port groups are automatically enabled in the process? (Choose two.)

  • A. Forged Transmits
  • B. Jumbo Frames
  • C. Promiscuous Mode
  • D. MacLearning
  • E. DVFiltering

Answer: A,C

 

NEW QUESTION 38
An architect is working with an All-Flash vSAN configuration and will be using the Flash Caching Devices in vSAN.
Which requirement is specifically needed for these devices?

  • A. IOPS
  • B. Read endurance
  • C. Write endurance
  • D. Capacity

Answer: C

Explanation:
Reference:
In all-flash configurations, vSAN uses the cache layer for write caching only. The write cache must be able to handle high write activities. https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.vsan-planning.doc/GUID-1D6AD25A-459A-43D6-8FF5-52475499D6A2.html

 

NEW QUESTION 39
data centers, the customer relayed the following information:
* Highest possible mitigation during a host failure in terms of capacity.
* A constraint in this year's IT budget.
What should the architect recommend?

  • A. Enable IOInsight Metrics.
    A minimum cluster of 2 vSAN ROBO nodes.
  • B. Enable performance services.
    A minimum cluster of 6 vSAN nodes.
  • C. Enable operations reserve.
    A minimum cluster of 3 vSAN nodes.
  • D. Enable host build reserve.
    A minimum cluster of 4 vSAN nodes.

Answer: D

 

NEW QUESTION 40
A company has deployed a 12-node (6-6-1) vSAN 7.0 stretched cluster for all production workloads.
The customer currently uses four different vSAN storage policies for running the workloads depending on the applications requirements:
* Policy 1 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Erasure Coding
* Policy 2 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Mirroring
* Policy 3 - Site Disaster Tolerance=None - Keep Data on Preferred, FTT=Mirroring
* Policy 4 - Site Disaster Tolerance=None - Keep Data on Non-Preferred, FTT=Mirroring During the setup of the vSAN stretched cluster, the following VM/Host Rules were created:
* Preferred Site - Preferred Site workloads should run on DC1 hosts.
* Secondary Site - Secondary Site workloads should run on DC2 hosts.
Which two activities should the administrator complete to ensure that there is no impact to production services during the maintenance window in the Preferred Site? (Choose two.)

  • A. Update vSphere DRS site affinity rules so that Preferred Site workloads must run on hosts in DC2.
  • B. Update vSphere DRS site affinity rules so that Preferred Site workloads should not run on hosts in DC1.
  • C. Change the Site Disaster Tolerance setting in Policy 4 to be "None - Keep Data on Preferred".
  • D. Change the Site Disaster Tolerance setting in Policy 3 to be "Dual Site Mirroring".
  • E. Change the FTT setting in Policy 3 to be "Erasure Coding".

Answer: A,D

 

NEW QUESTION 41
A company has engaged a consultant to upgrade an existing vSAN cluster to vSAN 7.0 U1.
During the discovery phase, the consultant found the following information about the existing environment:
* The VMware vCenter Server has recently been upgraded from VMware vSphere 6.7 U3 to version 7.0 U1.
* The vSAN Cluster was recently expanded with identical hardware specification, but from a different hardware vendor.
* The hardware for each vSAN node is listed on the vSAN Compatibility Guide (VCG) for vSAN 7.
* The vSAN Cluster has the following configuration:
- vSAN version: 6.6.1
- Number of vSAN nodes: 10
- Encryption: enabled
- Deduplication and Compression: enabled
- vSAN Capacity Utilization: 60%
* Each vSAN node has the following configuration:
- VMware vSphere ESXi version: 6.5 Update 3
- CPU: 2 processors, 20 cores
- RAM: 768GB RAM.
- Disk: 2 Cache SSDs and 6 Capacity SSDs
- Network: 4 x 10GbE
Which three recommendations should the consultant make to ensure all data remains protected in the event of a vSAN failure? (Choose three.)

  • A. The Ensure accessibility, migration maintenance mode option must be chosen to protect the data during the upgrade.
  • B. The Full data migration maintenance mode option must be chosen to protect the data during the upgrade.
  • C. The upgrade process should be completed using host upgrade baselines in VMware vSphere Lifecycle Manager (vLCM).
  • D. The upgrade process should be completed using images in VMware vSphere Lifecycle Manager (vLCM).
  • E. The vSAN nodes should be upgraded to vSphere ESXi 7.0 U1.
  • F. The vSAN nodes should be upgraded to vSphere ESXi 6.7 U3.

Answer: A,D,E

 

NEW QUESTION 42
After a vSAN Witness Appliance network configuration, the vSAN administrator notices that vSAN traffic flows from vmk0 (Management Traffic) rather than vmk1 (vSAN Traffic).
Which step should be taken to resolve this issue?

  • A. Tag the vmk1 for Witness traffic.
  • B. Configure vmk0 with IP address on the same range as that of vmk1.
  • C. Tag the vmk0 for vSAN traffic.
  • D. Configure vmk1 with IP address on the different network than that of vmk0.

Answer: D

 

NEW QUESTION 43
......

5V0-21.21 Exam Questions: Free PDF Download Recently Updated Questions: https://latestdumps.actual4exams.com/5V0-21.21-real-braindumps.html